Resmed ApneaLink Air Sleep Test Device Supplier

Philips Respironics Alice NightOne Home Sleep Study Device Supplier

Respi Medical Systems is a respiratory and sleep-diagnostic equipment supplier serving healthcare requirements across Kolkata, West Bengal, Bihar, Odisha, Jharkhand and Chhattisgarh. The Philips Respironics Alice NightOne Home Sleep Study Device is a compact portable sleep-testing system designed to record important physiological signals during a home sleep study. The device is intended to support the assessment of sleep-related breathing disorders, particularly suspected obstructive sleep apnea. Its patient-oriented setup features, built-in body-position sensing and signal-quality guidance make it suitable for home sleep-testing workflows under appropriate clinical supervision. Philips describes Alice NightOne as a home sleep testing solution with features such as Auto-On, a smart guide, Good Study Indicator and integrated body-position sensing.

Philips Respironics Alice Night One Home Study Screening Device for Sleep Disorder Treatment

The Philips Respironics Alice Night One Home Study Screening Device is designed to record physiological information while the patient sleeps at home. The collected data can be reviewed by qualified healthcare professionals to support the evaluation of sleep-disordered breathing and subsequent treatment planning. Alice NightOne records parameters including airflow, snoring, thoracic respiratory effort, oxygen saturation, pulse rate, body position and plethysmography. It can also record optional therapy channels when used with compatible Philips Respironics therapy devices. It is important to distinguish the diagnostic role of the device from treatment: Alice NightOne does not itself treat sleep apnea or another sleep disorder. Instead, the sleep-study information can help a qualified clinician determine whether further diagnostic evaluation or appropriate treatment may be required.

Product Profile

The Philips Respironics Alice Night One is a portable home sleep-testing device designed around a simplified patient setup. It combines a compact recording unit with sensors used to collect respiratory and physiological information during sleep.

The system is particularly designed to make home testing easier through features such as:

  • Auto-On recording
  • Smart Guide patient setup
  • Integrated body-position sensing
  • Good Study Indicator
  • Thoracic respiratory-effort measurement
  • SpO₂ monitoring
  • Pulse-rate recording
  • Airflow and snoring measurement
  • Portable data recording
  • Compatibility with Sleepware G3 software
  • Optional therapy-channel connectivity with compatible Philips Respironics devices

Key Features of Philips Alice NightOne

  • Auto-On Function

The Auto-On feature is designed to start recording when the device is correctly buckled and prepared for the study, simplifying the starting process for home users.

  • Smart Guide Patient Setup

Alice NightOne incorporates a Smart Guide sequence intended to guide patients through setup and provide indications related to sensor connections and signal quality.

  • Integrated Body Position Sensor

The device includes built-in body-position sensing. Philips specifies reporting for positions including supine, prone, right side, left side and upright.

  • Good Study Indicator

The Good Study Indicator provides information regarding the quality and quantity of recorded signals. This can help clinicians identify whether signals were adequately captured during the study.

  • Portable Home Sleep Testing

Its compact size and battery operation make it suitable for portable sleep-testing workflows where a patient performs the study outside a conventional sleep laboratory.

  • Optional Therapy Channels

When connected with compatible Philips Respironics therapy devices, Alice NightOne can record selected therapy channels, depending on the therapy device and operating mode.

Connect Us

Feel free to contact us anytime for any assistance. We are always here to provide you with the best possible service and support.

Technical Specifications

Specification

Philips Respironics Alice NightOne

Product Type

Portable Home Sleep Testing Device

Total Channels

7 channels plus optional therapy channels

Recorded Parameters

Flow, snore, thoracic effort, SpO₂, pulse rate, body position and pleth

Body Position

Supine, prone, right, left and upright

Good Study Indicator

Yes

Internal Storage

4 GB

Communication

USB to PC; wireless communication with compatible Philips Respironics devices

Oximetry Sampling Rate

62.5 Hz

Power

Two AA batteries

Dimensions

Approx. 10.34 × 2.51 × 6.78 cm

Weight

Approx. 84 g without sensors or batteries

Software

Sleepware G3

Recording Type

Portable home sleep study

Specifications may vary according to configuration, accessories and market.

Sleep Parameters Recorded by Alice NightOne

The device can capture several important signals used in home sleep testing:

  • Airflow

Airflow information can help clinicians evaluate changes in breathing during sleep.

  • Snoring

The snore channel provides information that may be relevant when assessing sleep-disordered breathing.

  • Thoracic Effort

Respiratory-effort measurement helps record chest movement during breathing.

  • SpO₂

The pulse oximetry system records oxygen saturation during the study.

  • Pulse Rate

Pulse-rate information can be recorded alongside oxygen saturation.

  • Body Position

The integrated sensor identifies different body positions during the recording.

  • Plethysmography

Pleth information is recorded as part of the oximetry measurement.

Together, these channels provide a multi-parameter record that can be reviewed as part of an appropriate home sleep-testing assessment.

Alice NightOne for Home Sleep Study

A home sleep study allows appropriate patients to undergo selected sleep-related diagnostic testing outside a conventional sleep laboratory.

A typical workflow may include:

  • Patient assessment – A qualified healthcare professional determines whether home sleep testing is appropriate.
  • Device preparation – The Alice NightOne device and required sensors are configured.
  • Patient instruction – The patient receives guidance on applying the sensors and operating the device.
  • Overnight recording – The device records the selected physiological signals while the patient sleeps.
  • Data retrieval – The recorded study is transferred for clinical review.
  • Clinical interpretation – A qualified professional reviews the recorded information and determines the appropriate next step.

Philips provides educational material covering Alice NightOne configuration, patient setup, sensor application and data retrieval.

Philips Alice NightOne for Sleep Disorder Screening

The Alice NightOne can be used in suitable home-testing workflows for patients being evaluated for sleep-disordered breathing. Its combination of airflow, respiratory effort, oxygen saturation, pulse, snoring and body-position information allows multiple aspects of nighttime breathing to be recorded.

It may be relevant for:

  • Suspected obstructive sleep apnea screening
  • Home sleep testing
  • Sleep-disordered breathing assessment
  • Respiratory sleep studies
  • Follow-up testing where clinically appropriate
  • Sleep clinic diagnostic workflows
  • Home-based sleep diagnostic programs

The final diagnosis should be made by a qualified healthcare professional based on the sleep-study data and the patient’s overall clinical assessment.

Sleepware G3 Software Compatibility

Philips’ Sleepware G3 software platform supports both in-lab Alice PSG studies and portable sleep-testing devices, including Alice NightOne. The platform provides functions for study acquisition, scoring and physician review. This allows recorded sleep-study information to be incorporated into an organized diagnostic workflow rather than relying only on the device itself.

Philips Respironics Alice Night One Home Study Screening Device Supplier

Respi Medical Systems supplies respiratory and sleep-diagnostic equipment solutions for customers searching for the Philips Respironics Alice Night One Home Study Screening Device in:

  • Kolkata
  • West Bengal
  • Bihar
  • Odisha
  • Jharkhand
  • Chhattisgarh

Our product portfolio is intended to support requirements from hospitals, sleep clinics, diagnostic centers, healthcare institutions and other professional healthcare users.

Common Applications

  • Sleep Clinics

Alice NightOne can support selected home sleep-testing programs managed by sleep specialists and qualified healthcare teams.

  • Hospitals

Hospitals can consider portable sleep diagnostic systems for appropriate patients where home-based testing is clinically suitable.

  • Diagnostic Centers

The device can be incorporated into sleep diagnostic workflows requiring portable recording and subsequent professional data analysis.

  • Home Sleep Testing

Its compact design and patient-guidance features make it particularly relevant to home-based sleep-study workflows.

  • Sleep Apnea Screening

The combination of respiratory-effort, airflow, SpO₂, snoring and body-position information can support the clinical evaluation of suspected sleep-disordered breathing.

Why Choose Respi Medical Systems?

Respi Medical Systems provides respiratory-care and sleep-diagnostic equipment solutions across Kolkata, West Bengal, Bihar, Odisha, Jharkhand and Chhattisgarh.

  • Application-Based Product Assistance

We help customers understand the intended application, required configuration, accessories and equipment requirements before procurement.

  • Respiratory Equipment Expertise

Our product range includes sleep-diagnostic equipment as well as CPAP, Auto CPAP, BIPAP/NIV machines, masks, tubing, oxygen concentrators, ventilators and related respiratory-care products.

  • Support for Healthcare Institutions

We cater to requirements from hospitals, clinics, sleep laboratories, diagnostic centers and other healthcare organizations.

  • Regional Availability

Customers across Kolkata, West Bengal, Bihar, Odisha, Jharkhand and Chhattisgarh can contact Respi Medical Systems regarding product availability and sourcing requirements.

Quality and Equipment Configuration

For a home sleep-testing system, appropriate sensor configuration, patient instructions, data management and professional interpretation are important parts of the overall diagnostic process.

Alice NightOne provides seven primary recorded channels, with optional therapy channels depending on the compatible therapy device and configuration.

Respi Medical Systems can assist healthcare customers in understanding the equipment configuration and accessories required for their intended application.

Important Product Availability Information

Philips currently lists Alice NightOne as a discontinued Sleep Diagnostic Machine. According to Philips’ portfolio update, sales and shipments were discontinued on January 25, 2024, with an end-of-service date of January 25, 2029. Availability and service arrangements may vary by market. Therefore, customers looking for a Philips Respironics Alice NightOne should confirm the available condition, accessories, software compatibility, service status and applicable support arrangements before purchase.

Contact Respi Medical Systems

If you are searching for a Philips Respironics Alice NightOne Home Sleep Study Device Supplier in Kolkata, West Bengal, Bihar, Odisha, Jharkhand or Chhattisgarh, contact Respi Medical Systems for product information and availability enquiries. We can assist hospitals, sleep clinics, diagnostic centers and healthcare institutions with respiratory and sleep-diagnostic equipment requirements. Contact Respi Medical Systems today for Philips Respironics Alice NightOne enquiries, home sleep-testing equipment requirements and sleep-diagnostic solutions.